According to a study from Tours, France, "The aim of this study was to identify the origin of swallowing sound components by using modern techniques that can provide numeric, synchronized acoustic-radiologic data. We enrolled 15 volunteer subjects (10 men and 5 women, average age = 29.5 +/- 8 years) and used an X-ray camera connected to a video acquisition card to obtain synchronized acoustic-radiologic data (25 images/s)."
"The subjects were asked to swallow 10 ml of a barium suspension. Each sound component was associated with a specific position of the bolus and the anatomic structure that was moving. The average duration of the pharyngeal sound was 690 +/- 162 ms. The durations of the laryngeal ascension sound and the laryngeal release sound were significantly different (72 +/- 38 ms and 106 +/- 47 ms, p
The researchers concluded: "This study allowed us to determine the origin of the three main sound components of the pharyngeal swallowing sound with respect to movements in anatomic structures and the different bolus positions."
Moriniere and colleagues ...