2003 SEP 4 - (NewsRx.com & NewsRx.net) -- Patient position affects the analysis of pelvic organ prolapse.
"The pelvic organ prolapse quantification system (POP-Q) is currently the most quantitative, site-specific system for describing pelvic organ prolapse. To ensure that anatomic outcomes can be optimally assessed, investigators in the Pelvic Floor Disorders Network evaluated the impact of specific technique variations on POP-Q measurements performed on 133 patients by 16 examiners at 7 sites. Values for genital hiatus and perineal body were higher when measured with maximal strain than on resting," scientists in the United States reported.
"With the exception of TVL, internal points did not differ significantly when measured with or without a speculum. The maximum extent of prolapse was best seen with the patient standing," A.G. Visco and colleagues, University Michigan, School of Public Health advised.